First, notice what the system is doing
- Nothing starts: confirm a Heat request, then check thermostat and equipment power.
- Air moves but feels cool: set a ducted fan to Auto and allow a brief defrost to finish.
- It runs but the house stays cold: restore airflow, clear the outdoor unit and watch the room temperature.
- Turn the system off for burning smells, electrical sounds, repeated breaker trips or heavy ice.
A heat pump moves outdoor heat indoors. Its supply air can feel gently warm instead of hot, and it briefly interrupts heating to clear frost from the outdoor coil. We'd start at the thermostat because a missed Heat call or fan left On can mimic failed heating.
| What you see | What it can mean | First move |
|---|---|---|
| Nothing starts | No Heat request or lost equipment power | Set Heat above room temperature, then look at the indoor switch and labeled breakers. |
| Air moves but stays cool | Fan-only airflow, defrost or failed heating | Set a ducted fan to Auto; see whether warmth returns after defrost. |
| It runs without warming the room | Restricted airflow, cold-weather demand or lost heating capacity | Clean the filter, clear outdoor debris and compare room-temperature readings. |

Make sure the thermostat is asking for heat
- If the screen is blank and the thermostat uses replaceable batteries, fit fresh batteries of the type marked for it. Select Heat on the thermostat or affected ductless head. Set its target above the displayed room temperature and note both readings. Look for Heat On, a flame icon or another heat-call indication.
- On a ducted system, set Fan to Auto. Fan On can circulate room-temperature air without a heating cycle; with Auto, the fan should run with a heat call.
- If the target changes back, read the active schedule and use Hold or its schedule control to keep your intended target.
- If Heat On or Waiting flashes after a change, allow about 5 minutes for compressor protection. Heating equipment should then respond, followed by a room-temperature reading that holds or rises.
If the target stays put but no heat call appears, the control needs diagnosis after the power check. If a heat call appears and both indoor and outdoor equipment remain silent, move to the switches and breakers.
Let air move through the indoor unit
Weak airflow or a running heat pump that doesn't warm the room calls for a filter inspection. A loaded filter reduces heating and can trigger shutdown. Keep service panels closed.
- Turn the system off. For a ducted system, pull the filter from its slot beside the air handler or furnace, or from behind a large return grille. For a ductless head, lift its owner filter cover and look for dust.
- Replace a dirty disposable filter. Rinse a washable filter and let it dry completely before reinstalling it. The reusable-filter cleaning steps help if yours can be washed.
- Move furniture or curtains away from return grilles. In a ducted room with weak airflow, open its supply register and clear anything blocking it.
- Restore Heat. Airflow should improve, followed by a steady or rising room temperature. If airflow remains weak throughout the house, continue to the service handoff.
If part of the system is silent, check its power
A split ducted heat pump has separate indoor and outdoor circuits. Its indoor fan can run without outdoor power, so listen for each section during a heat call.
- If you smell burning or an electrical odor, hear buzzing or arcing, or see heat or visible damage, stop troubleshooting and call an HVAC technician before turning a switch On. Look at the indoor service switch beside the air handler and the outdoor disconnect's external switch. Turn either switch On if it was Off.
- At the household electrical panel, look for labeled indoor and outdoor HVAC breakers without removing its cover. A tripped handle may rest between On and Off.
- Follow the equipment's breaker-reset instruction. If it allows one reset and there is no heat, damage, burning odor or electrical noise at the breaker, move the tripped handle fully Off, then On once.
- Allow about 5 minutes if the thermostat shows a startup delay. Power restoration should bring the equipment back into a heating cycle; if it stays silent or the breaker trips again, the power check has reached its limit.
Keep hands away from damaged or hot electrical equipment.
Give the outdoor unit room to breathe
- Turn the system off at its normal control before working close to the unit.
- Move loose snow and debris away from the top and sides by hand or with a soft broom. Keep the broom away from the coil and fan, and leave attached ice alone.
- Leave roughly 18 to 24 inches of open space around the cabinet and keep its top clear. Restore any larger clearance marked for your unit, then restart Heat.
The outdoor unit should run without blockage and the room should begin warming. If it does not, look for defrost or ice on the coil.
Cool-feeling air may be normal for a short spell
During an active heating cycle, air at a ducted register is commonly around 85 to 100°F. That can feel lukewarm on your hand. A room that holds its temperature or warms tells you more than the feel of one vent.
In cold, damp weather, light frost, steam, a whoosh or a stopped outdoor fan can mark defrost. Leave Heat selected and watch from a distance. Defrost commonly takes about 5 to 15 minutes; frost should clear and heating should resume. The US Department of Energy's air-source heat pump guidance (opens in a new tab) explains the pause.
If the indoor fan keeps moving cold air, confirm Fan Auto and a heat call. Cold air after defrost, an outdoor fan stopped outside defrost, or returning ice points toward a fan, defrost-control, refrigerant or reversing-valve fault.
It runs all day but never reaches the setting
Long operation can be normal during severe cold because the house needs more heat. In mild weather, continuous running while the room stays below the target deserves a closer look. We'd hold the target steady: raising it repeatedly can call for backup heat and obscure what the heat pump is doing.
- Write down the displayed room temperature, target, outdoor conditions and time. Note whether the thermostat shows AUX.
- Leave the target steady, make sure the filter and grilles are clear, and allow any defrost cycle to finish.
- After about an hour, note whether the displayed room temperature rose, held steady or fell.
In severe cold, a steady or rising reading shows the system is supplying heat. A falling reading, or a persistent gap in mild weather after the airflow and outdoor checks, points toward lost capacity or missing backup. If one ducted room is cold, clear its register and return; if every room is cold, focus on the whole system.
Hissing or repeated icing strengthens suspicion of a refrigerant leak. Cooling that worked before heating failed points toward the reversing valve, which changes refrigerant direction. Internal controls or the compressor can also prevent heating; those parts require equipment tests, not another thermostat adjustment.
In freezing weather, see whether backup heat answers
A system with backup heat calls for AUX automatically when it needs extra heat. Electric backup uses strips in the indoor air handler.
If the thermostat shows AUX Heat On or a similar status, look for warmer air and a rising room-temperature reading. If a home with known backup keeps cooling and AUX never appears, the thermostat's staging or heat-pump capacity needs diagnosis. If AUX appears without warmth, make the external backup checks below.
- For electric strips, look at the service switch beside the indoor air handler and its labeled breaker. Use the one-reset rule above, then hold the target steady and see whether the room warms.
- For dual fuel, which switches to a furnace, see whether the furnace is being called. Heat pump and furnace operation explains the difference. Look at its power switch and labeled breaker before examining its external fuel supply.
- For a gas furnace with no gas odor, confirm that its external manual valve is open, with its handle parallel to the pipe. For propane or oil, confirm fuel remains in the tank. From outside, clear loose snow from blocked furnace intake or exhaust openings without dismantling piping.
- Watch for the furnace to run and the room temperature to rise. A backup call without warming after these checks means the backup source itself needs prompt diagnosis.
Emergency Heat is a manually selected mode on thermostats that offer it. If the outdoor heat pump has failed and backup works, select it temporarily and confirm the house warms; return to normal Heat after repair. The outdoor compressor stays off. Electric strips can raise the electric bill, while a dual-fuel furnace's running cost depends on fuel and electricity prices.
What the remaining fault can cost
If the system stays silent, blows cold after defrost or loses room temperature, book a qualified HVAC contractor familiar with your setup. Report the Heat target and room reading, Heat On or AUX status, which sections ran, filter and coil condition, breaker trips, hissing, ice, error codes and whether cooling worked before heating stopped.
A diagnostic visit is $75 to $200 for a residential heat pump, with repair extra. For an ordinary ducted split system with a confirmed failed compressor, replacement is $800 to $2,700: the compressor is $500 to $1,500 and the job bills 4 to 8 hours at $75 to $150 an hour. One middle build is about $1,680, using about $1,000 in parts and 6 hours of labor.
| Confirmed scope | Installed price | What it covers |
|---|---|---|
| No-heat diagnostic visit | $75 to $200 | One service call and diagnosis; repair is extra. |
| Ordinary split-system compressor | $800 to $2,700 | Compatible compressor and replacement labor. |
| Installed air-source heat pump | $4,000 to $12,000 | Broad installed-job benchmark; ask which equipment and labor the quote includes. |
For an expensive compressor, coil or refrigerant-circuit repair, compare the itemized quote with outdoor-only and matched-system replacement quotes. Weigh compatibility, repeated failures and warranty coverage alongside age. Shops mark parts up over retail, so a quote's parts line can exceed retail equipment prices.
A typical included manufacturer warranty pays for eligible defective parts but leaves diagnosis and labor to the owner; some plans include limited labor. Confirm coverage against the certificate and serial number before approving work. In the US, opening the refrigerant circuit for gauges, charging or sealed-part replacement requires an EPA Section 608 certified technician (opens in a new tab).
Questions that come up next
What if only one room on my ductless heat pump will not heat?
Set that head to Heat above its room temperature, turn it off to clean and fully dry its owner-accessible filter, then clear its intake and outlet. On a standard multizone system, match the other heads to Heat or turn a conflicting Cool request off. If the other heads heat but this one stays cold after startup or defrost, record its zone and error display for a ductless-service technician.
Can I leave Emergency Heat on until the heat pump is fixed?
Unlike automatic AUX, Emergency Heat stays selected until you return to Heat after repair. Watch the displayed room temperature: if backup cannot keep it from falling, arrange prompt service. Electric strips cost more to run than the heat pump; a furnace's cost follows fuel prices. Burning smells or electrical sounds mean turn the system off.
How can I stop this from happening again?
Check a central system's filter about once a month and replace a dirty disposable filter, commonly every 30 to 90 days. Keep loose snow and debris off the outdoor unit, preserve its roughly 18 to 24 inches of open space, and schedule service before each heating season. Record ice that survives defrost, falling room temperature and any repeated breaker trip so a recurring fault can be traced.